Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-12 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	73
Date	08/12/14
Start Time	11:59:21
Diameter Midpoint
 10.9	156.626
 11.3	789.361
 11.8	809.557
 12.2	803.301
 12.6	545.681
 13.1	519.551
 13.6	292.939
 14.1	487.236
 14.6	220.018
 15.1	359.502
 15.7	300.914
 16.3	153.59
 16.8	210.75
 17.5	226.552
 18.1	208.908
 18.8	243.15
 19.5	423.163
 20.2	893.541
 20.9	1366.27
 21.7	1498.07
 22.5	1466.35
 23.3	1287.32
 24.1	1304.12
 25.0	1365.14
 25.9	1317.25
 26.9	1106.08
 27.9	1074.55
 28.9	801.884
 30.0	626.746
 31.1	437.611
 32.2	245.598
 33.4	179.76
 34.6	33.4775
 35.9	0
 37.2	0
 38.5	0
 40.0	0
 41.4	0
 42.9	521.321
 44.5	1991.23
 46.1	3729.12
 47.8	5068.07
 49.6	6109.08
 51.4	6552.52
 53.3	6994.1
 55.2	7165.94
 57.3	7072.83
 59.4	6745.44
 61.5	6766.12
 63.8	6364.7
 66.1	5768.93
 68.5	5055.9
 71.0	4824.33
 73.7	4611.09
 76.4	4459.7
 79.1	3855.25
 82.0	3020.4
 85.1	2388.37
 88.2	2312.67
 91.4	2041.88
 94.7	1918.83
 98.2	1853.39
101.8	1627.67
105.5	1410.62
109.4	1284
113.4	1089.75
117.6	926.621
121.9	756.512
126.3	501.493
131.0	455.241
135.8	306.497
140.7	261.732
145.9	175.435
151.2	150.735
156.8	118.551
162.5	95.5514
168.5	78.0513
174.7	70.8873
181.1	68.514
187.7	48.0678
194.6	45.6095
201.7	46.3976
209.1	46.9989
216.7	21.4233
224.7	29.0341
232.9	16.6246
241.4	18.0186
250.3	12.06
259.5	14.8778
269.0	9.59675
278.8	14.4335
289.0	8.51114
299.6	8.08304
310.6	6.28672
322.0	3.98707
333.8	9.07266
346.0	3.62865
358.7	2.1707
371.8	2.2092
385.4	2.24922
399.5	2.27625
414.2	6.95698
429.4	0
445.1	0
461.4	2.44135
478.3	0
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.14
High Voltage	9876.07
Lower Size(nm)	10.7461
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1076.23
Median(nm)	59.0615
Mean(nm)	61.1405
Geo. Mean(nm)	54.8408
Mode(nm)	55.2316
Geo. Std. Dev.	1.65674
Total Concentration(#/cm)	138705
Comment	
